PlantWare ApS
Skovlytoften 4, DK-2840 Holte
Phone +45 4541 4157, Fax: +45 4541 4158
Web: www.plantware.dk and Mail: info@plantware.dk
 
Pipe Design ValidationSoftware version 6. august 2001 - 9:10
Project:CMC Biotech A/S
Project number:067
Project description:Ny CMO factory
Date: 16 Sep 2011Time: 19:20
General describtion of the validation
Validation conducted by: SYSTEMSystem login: ChristianPallesen
Following papameters used:
Fall minimum:10/1000 = 0.5729Deg
Check for distance innerside Pipe to P0 in valve3 * Nominel Bore
Bend and Elbow radius bigger than1 * Nominel Bore
Legal length of tube pieces without fall 5 * Nominel Bore

Pipe nameDrainDead Legs Bend/Elbow radiusOrientation ValvesHeadTailSpec.
/B01-004 OK OK OK FAIL OK OK OK
/B01-005 FAIL OK OK FAIL OK OK OK

 

End of Report


This application was developed by PlantWare